Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi P-14 — Konica-Minolta bizhub C258

Code: P-14

Description: Skew correction trouble. The difference between the skew default position setting value and the cumulative amount of skew adjustment values goes over the predetermined value.
Causes: • IDC sensor/Fr (IDCS/Fr) • IDC sensor/Rr (IDCS/Rr) • Drum unit/Y,M,C,K • PH relay board (PHRYB) • Front side board (FRB) • MFP board (MFPB) • PH unit
Remedy: 1. Check the drive transmission portion of the drum unit and correct as necessary. 2. Clean the contact of the drum unit connector if dirty. 3. Reinstall or reconnect IDCS/Fr assy or IDCS/Rr assy, sensor shutter or connector, if it is installed or connected improperly. 4. Clean IDCS/Fr or IDCS/Rr if it is dirty. 5. Check the FRB connector for proper connection and correct as necessary. 6. Check the PHRYB connector for proper connection and correct as necessary. 7. Check the connectors of the MFPB for proper connection and correct as necessary. 8. FRB fuse conduction check. 9. Replace FRB. 10. Replace IDCS/Fr assy or IDCS/Rr assy. 11. Replace the drum unit. 12. Replace the PH unit. 13. Replace PHRYB. 14. Replace MFPB NOTE • After the PH unit is replaced, reset the skew default position for each color in [Service Mode] -> [Machine] -> [Print Head Skew Adj.] -> [Print Head Skew Adj.] • When this alert code is displayed, according to the list, take actions to address the problem. After the problem is resolved, select [Service Mode] -> [Machine] -> [Print Head Skew Adj.] -> [Print Head Skew Reset] and perform the skew adjustment reset.

← Xem tất cả mã lỗi Konica-Minolta bizhub C258

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie