Description: Secondary transfer ATVC failure. An abnormal average value is detected during an adjustment of the second transfer ATVC value.
Causes: • High voltage unit (HV) • MFP board (MFPB) • Image transfer entrance guide • 2nd transfer assy • Transfer belt unit
Remedy: 1. Check the contact between the roller opposed to the 2nd transfer roller in the transfer belt unit and the grounding terminal. Clean the joint or correct if necessary. 2. Check the image transfer entrance guide for proper installation and correct if necessary. 3. Check that the spring does not come off during the pressure operation of the 2nd transfer roller and correct if necessary. 4. Check the contact at the joint of the 2nd transfer assy and HV. Clean the joint or correct if necessary. 5. Replace the transfer belt unit. 6. Replace HV. 7. Replace MFPB.