Code: C1145
Description: Trailing edge stopper motor’s malfunction
<When FS-534 is installed> The trailing edge stopper home position detection sensor (PS20) is not blocked or unblocked even after the set period of time has elapsed after the trailing edge stopper motor (M6) is turned ON.
<When FS-534 is installed> The trailing edge stopper home position detection sensor (PS20) is not blocked or unblocked even after the set period of time has elapsed after the trailing edge stopper motor (M6) is turned ON.
Remedy: 1 Check the connector between M6-FSCB J5 for proper connection, and correct as necessary. 2 Check the connector of M6 for proper drive coupling, and correct as necessary. 3 Check the connector between PS20-relay CN22-FSCB J5 for proper connection, and correct as necessary. 4 PS20 I/O check, sensor check FSCB J5-9 (ON) FS-534 9-K. 5 M6 operation check FSCB J5-13 to 16 FS-534 9-K. 6 Replace M6. 7 Replace FSCB.