Description: Tray 2 feeder up/down abnormality. The tray 2 upper limit sensor (PS22) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Remedy: 1. Remove the tray and check to see if a piece of paper is not left inside the machine. 2. Check the connector between M13-MFPB CN7E for proper connection and correct as necessary. 3. Check the connector of M13 for proper drive coupling and correct as necessary. 4. Check the connector between PS22-relay CN55-MFPB CN5E for proper connection and correct as necessary. 5. PS22 I/O check, sensor check • Control signal: MFPB CN5E<B>-9 (ON) • Location of electrical component: 11-C 6. M13 operation check • Control signal: MFPB CN7E<A>-13 to 14 • Location of electrical component: 23-C 7. Replace M13. 8. MFPB F13E conduction check 9. Replace MFPB. NOTICE • Link to the wiring diagram (N.1. bizhub C287/C227) • Link to the layout drawings for related parts by each trouble code (S.7. C0204)