Code: C0210
Description: LCT lift failure (When PC-414 is installed) • The main tray upper limit sensor (PS136) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. • The shifter stop / lower limit position sensor (PS138) is not turned OFF (unblocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. • The main tray upper limit sensor (PS136) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operating. • The main tray upper limit sensor (PS136) is not turned OFF (unblocked) even after the set period of time has elapsed after the paper lift-down operation began. • The shifter stop / lower limit position sensor (PS138) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-down operation began.
Causes: • Main tray upper limit sensor (PS136) • Shifter stop / lower limit position sensor (PS138) • Elevator motor (M134) • PC control board (PCCB) • MFP board (MFPB)
Remedy: 1. Remove the tray and check to see if a piece of paper is not left inside the machine. 2. Check the connector between M134-PCCB CN10L for proper connection and correct as necessary. 3. Check the connector of M134 for proper drive coupling and correct as necessary. 4. Check the connector between PS136-relay CN1-PCCB CN4 for proper connection and correct as necessary. 5. Check the connector between PS138-relay CN16-PCCB CN14L for proper connection and correct as necessary. 6. PS136 I/O check, sensor check • Control signal: PCCB CN4-3 (ON) • Location of electrical component: PC-414 8-J 7. PS138 I/O check, sensor check • Control signal: PCCB CN14L-6 (ON) • Location of electrical component: PC-414 3-J 8. M134 operation check • Control signal: PCCB CN10L-1 to 2 • Location of electrical component: PC-414 6-J 9. Replace M134. 10. Replace PCCB. 11. MFPB F11E conduction check 12. Replace MFPB. NOTICE • Link to the wiring diagram (N.2.4 PC-414) • Link to the layout drawings for related parts by each trouble code (S.10. C0210)