Description: Transfer belt spacing fault at K pressure switching. The 1st transfer pressure sensor (PS39) does not detect “switch from pressure to retraction” within a given period time after 1st transfer pressure clutch (CL5) has stared engagement.
Causes: • Fusing motor (M3) • 1st transfer pressure clutch (CL5) • 1st transfer pressure sensor (PS39) • MFP board (MFPB)
Remedy: 1. Check the connector between M3-MFPB CN11E for proper connection and correct as necessary. 2. Check the connector of M3 for proper drive coupling and correct as necessary. 3. Check the connector between PS39-relay CN24-MFPB CN7E for proper connection and correct as necessary. 4. Check the connector between CL5-relay CN29-MFPB CN12E for proper connection and correct as necessary. 5. PS39 I/O check, sensor check • Control signal: MFPB CN7E<B>-13 (ON) • Location of electrical component: 22-C 6. CL5 operation check • Control signal: MFPB CN12E-12 (ON) • Location of electrical component: 5-C 7. M3 operation check • Control signal: MFPB CN11E-11 (REM), MFPB CN11E-14 (FGP) • Location of electrical component: 3-C 8. Replace M3. 9. MFPB F13E conduction check 10. Replace MFPB. NOTICE • Link to the wiring diagram (N.1. bizhub C287/C227) • Link to the layout drawings for related parts by each trouble code (S.39. C2152, C2153, C2154, C2155, C2156)