Mã lỗi C2153 — Konica-Minolta bizhub C287

Code: C2153

Description: Transfer belt spacing fault at K pressure switching. The 1st transfer pressure sensor (PS39) does not detect “switch from pressure to retraction” within a given period time after 1st transfer pressure clutch (CL5) has stared engagement.
Causes: • Fusing motor (M3) • 1st transfer pressure clutch (CL5) • 1st transfer pressure sensor (PS39) • MFP board (MFPB)
Remedy: 1. Check the connector between M3-MFPB CN11E for proper connection and correct as necessary. 2. Check the connector of M3 for proper drive coupling and correct as necessary. 3. Check the connector between PS39-relay CN24-MFPB CN7E for proper connection and correct as necessary. 4. Check the connector between CL5-relay CN29-MFPB CN12E for proper connection and correct as necessary. 5. PS39 I/O check, sensor check • Control signal: MFPB CN7E<B>-13 (ON) • Location of electrical component: 22-C 6. CL5 operation check • Control signal: MFPB CN12E-12 (ON) • Location of electrical component: 5-C 7. M3 operation check • Control signal: MFPB CN11E-11 (REM), MFPB CN11E-14 (FGP) • Location of electrical component: 3-C 8. Replace M3. 9. MFPB F13E conduction check 10. Replace MFPB. NOTICE • Link to the wiring diagram (N.1. bizhub C287/C227) • Link to the layout drawings for related parts by each trouble code (S.39. C2152, C2153, C2154, C2155, C2156)

← Xem tất cả mã lỗi Konica-Minolta bizhub C287

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie