Description: Transfer belt cleaner cooling fan failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Transfer belt cleaner cooling fan (FM2) • MFP board (MFPB)
Remedy: 1. Check the connector between FM2-relay CN139-relay CN22-MFPB CN15E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM2 operation check • Control signal: MFPB CN15E<B>-10 (REM), MFPB CN15E<B>-12 (LOCK) • Location of electrical component: 16-C 4. Replace FM2. 5. Replace MFPB. NOTICE • Link to the wiring diagram (N.1. bizhub C287/C227) • Link to the layout drawings for related parts by each trouble code (S.41. C2355)