Description: Main backup media access error. • The re-written data, which has been read out, checked and founded as error, is read out again and found as error. • The error was found when reading out the counter value. • The main body detects that the EEPROM is not mounted.
Causes: • EEPROM/1 • EEPROM/2 • MFP board (MFPB)
Remedy: 1. Make sure that EEPROM/1 and EEPROM/2 are mounted in their respective correct positions. 2. Check to see if the EEPROM is mounted in a reverse direction. 3. Check the connector from MFPB to EEPROM for proper connection and correct as necessary. 4. Replace MFPB. 5. Replace EEPROM/1 and EEPROM/2. 1. Replace the current EEPROM with a new one. 2. Replace the following components with new ones. When the transfer belt unit and the fusing unit have been replaced with new ones, perform [New Release] in the service mode. When the transfer roller has been replaced with a new one, perform [Counter clear]. • Imaging unit/Y,M,C • Developing unit/K • Drum unit/K • Transfer belt unit • Fusing unit • Transfer roller • Feed roller, pick-up roller, separation roller (including options) 3. Turn ON the main power switch and check to see that warm-up is started. Make sure that malfunction codes other than C2650 or improper IU/TC placement is not detected. 4. Make the specified readjustments. 6. If the above actions do not solve the problem, contact KM. NOTICE • Link to the layout drawings for related parts by each trouble code (S.50. C2650, CC163)