Mã lỗi C392B — Konica-Minolta bizhub C287

Code: C392B

Description: Fusing sensor wire breaks detection (Center of the heating roller). The difference between the temperature corrected by the heating roller thermistor/1 (TH1) and the temperature detected by the heating roller thermistor/2 (TH2) exceeds a predetermined value.
Causes: • Fusing unit • Heating roller thermistor/1 (TH1) • Heating roller thermistor/2 (TH2) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the connector between the fusing unit-relay CN4-MFPB CN16E for proper connection and correct as necessary. 4. Replace the fusing unit. 5. Replace MFPB. NOTICE • Link to the layout drawings for related parts by each trouble code (S.59. C392B)