Description: Clean unit fan failure to turn (When CU-101 is installed). The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Remedy: 1. Check the connector between CUDB CN1-MFPB CN29E for proper connection and correct as necessary. 2. Check the connector between FM14-CUDB CN2, FM15-CUDB CN3, FM16-relay CN81-CUDB CN4 for proper connection and correct as necessary. 3. Check the fan for possible overload and correct as necessary. 4. FM14, FM15, FM16 operation check • Load check: Check code42, Multi code 5 • Control signal: CUDB CN2 (FM14), CUDB CN3 (FM15), CUDB CN4 (FM16) • Location of electrical component: 12-U (FM16), 12-Y (FM14, FM15) 5. Replace the defective fan. (FM14 / FM15 / FM16) 6. Replace CUDB. 7. MFPB F16E conduction check 8. Replace MFPB. NOTICE • Link to the wiring diagram (N.1. bizhub C287/C227) • Link to the layout drawings for related parts by each trouble code (S.65. C5360)