Mã lỗi P-5, P-28 — Konica-Minolta bizhub C287

Code: P-5, P-28

Description: IDC sensor/Fr failure, IDC sensor/Rr failure. • During IDC sensor light intensity correction, output voltage detected for all eight sample patterns are 3.35 V or more. • During IDC sensor light intensity correction, sensor output voltage for light intensity selected after the correction is under 0.7 V. • During IDC base surface detective control, sensor output voltage detected is under 0.7 V or over 3.35V. • During image stabilization (gamma correction control), detected output value for IDC sensor did not go below threshold (half the value of what is detected by IDC sensor on the belt surface) for three consecutive times (position of the pattern end is not detected). • During image stabilization (gamma correction control), sensor’s output value of each color for hyper 0 gradation after the primary approximation is half the detection level on the belt surface or under
Causes: • IDC sensor/Fr (IDCS/Fr) • IDC sensor/Rr (IDCS/Rr) • High voltage unit (HV) • Transfer belt unit
Remedy: 1. Wipe clean the surface of the transfer belt with a soft cloth, if it is dirty. 2. Replace the transfer belt unit if the transfer belt is damaged. 3. Reinstall or reconnect IDCS/Fr or IDCS/Rr if it is installed or connected improperly. 4. Clean IDCS/Fr or IDCS/Rr if it is dirty. 5. Check the HV connector for proper connection and correct as necessary. 6. Open/close the front door, run an image stabilization sequence, and select [State Confirmation] -> [Level History 1] to check the IDC value. If the value is 1.0 V or less, replace IDCS/Fr or IDCS/Rr. 7. Replace MFPB

← Xem tất cả mã lỗi Konica-Minolta bizhub C287

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie