Description: Center-staple knife drive motor malfunction (When FS-534SD is installed) The center fold knife home sensor (PS8) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed after the center fold knife motor (M9) is turned ON.
Causes: • Center fold knife motor (M9) • Center fold knife home sensor (PS8) • SD drive board (SDDB) • FS control board (FSCB)
Remedy: 1. Check the connector between M9-SDDB J11 for proper connection and correct as necessary. 2. Check the connector of M9 for proper drive coupling and correct as necessary. 3. Check the connector between PS8-relay CN10-SDDB J7 for proper connection and correct as necessary. 4. PS8 I/O check, sensor check • Control signal: SDDB J7-3 (ON) • Location of electrical component: SD-511 6-G 5. M9 operation check • Control signal: SDDB J11-11 to 20 • Location of electrical component: SD-511 1 to 2-B 6. Replace M9. 7. Replace SDDB. 8. Replace FSCB.