Mã lỗi C1141 — Konica-Minolta bizhub C308

Code: C1141

Description: Paddle motor drive malfunction (When FS-534 or FS-534SD is installed) The upper paddle home position detection sensor (PS14) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed while the FNS paddle motor (M5) is turning.
Causes: • FNS paddle motor (M5) • Upper paddle home position detection sensor (PS14) • FS control board (FSCB)
Remedy: 1. Check the connector between M5-FSCB J4 for proper connection and correct as necessary. 2. Check the connector of M5 for proper drive coupling and correct as necessary. 3. Check the connector between PS14-FSCB J4 for proper connection and correct as necessary. 4. PS14 I/O check, sensor check • Control signal: FSCB J4<B>-7 (ON) • Location of electrical component: FS-534 13-C 5. M5 operation check • Control signal: FSCB J4<A>-9 to 12 • Location of electrical component: FS-534 12-C to D 6. Replace M5. 7. Replace FSCB.