Code: C2152 ... C2156
Description: • C2152: Transfer belt fault at initial position return • C2153: Transfer belt spacing fault at K pressure switching • C2154: Transfer belt contact fault at all pressure switching • C2155: Transfer belt contact fault after K pressure established • C2156: Transfer belt spacing fault after all pressure established. • C2152: The 1st transfer pressure sensor (PS39) is unable to detect "switch from retraction to pressure" or "switch from pressure to retraction" within a given period time after the 1st transfer pressure clutch (CL5) has stared engagement during an initial position return. • C2153: The 1st transfer pressure sensor (PS39) does not detect “switch from pressure to retraction” within a given period time after 1st transfer pressure clutch (CL5) has stared engagement. • C2154: The 1st transfer pressure sensor (PS39) does not detect “switch from retraction to pressure” within a given period time after 1st transfer pressure clutch (CL5) has stared engagement. • C2155: The 1st transfer pressure sensor (PS39) is blocked after the lamps of given time after the 1st transfer pressure clutch (CL5) turned OFF when the release operation is finished. • C2156: The 1st transfer pressure sensor (PS39) is unblocked after the laps of given time after the 1st transfer pressure clutch (CL5) turned OFF when the pressing operation is finished.
Causes: • Fusing motor (M3) • 1st transfer pressure clutch (CL5) • 1st transfer pressure sensor (PS39) • MFP board (MFPB)
Remedy: 1. Check the connector between M3-MFPB CN8E for proper connection and correct as necessary. 2. Check the connector of M3 for proper drive coupling and correct as necessary. 3. Check the connector between PS39-relay CN113-MFPB CN15EB for proper connection and correct as necessary. 4. Check the connector between CL5-relay CN118-MFPB CN15EA for proper connection and correct as necessary. 5. PS39 I/O check, sensor check • Control signal: MFPB CN15EB-17 (ON) • Location of electrical component: 10-C 6. CL5 operation check • Control signal: MFPB CN15EA-18 (ON) • Location of electrical component: 8-C 7. M3 operation check • Control signal: MFPB CN8E-9 (REM), MFPB CN8E-12 (LOCK) • Location of electrical component: 2-C 8. Replace M3. 9. MFPB ICP2E conduction check 10. Replace MFPB.