Mã lỗi C3722, C3725, C3726 — Konica-Minolta bizhub C308

Code: C3722, C3725, C3726

Description: • C3722: Fusing abnormally high temperature detection (Edge of the heating roller) • C3725: Fusing abnormally high temperature detection (Main of the heating side) • C3726: Fusing abnormally high temperature detection (Center of the heating side). • C3722: Detected temperature of the heating roller thermistor/1 (TH1) goes beyond a given temperature for a given period of time consecutively. • C3725: Detected temperature of the heating roller temperature sensor (TEMS) goes beyond a given temperature for a given period of time consecutively. • C3726: Detected temperature of the heating roller thermistor/2 (TH2) goes beyond a given temperature for a given period of time consecutively.
Causes: • Fusing unit • C3722: Heating roller thermistor/1 (TH1) • C3725: Heating roller temperature sensor (TEMS) • C3726: Heating roller thermistor/2 (TH2) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the fusing unit and MFPB for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB.

← Xem tất cả mã lỗi Konica-Minolta bizhub C308