Description: • C6102: Drive system home sensor malfunction • C6103: Slider over running. C6102: • The scanner home sensor (PS201) is unable to detect the scanner located at its home position. • The scanner home sensor (PS201) is unable to detect a scanner even when the scanner motor (M201) has been driven to move the scanner over the maximum travelling distance. • The scanner home sensor (PS201) detects the scanner when the scanner has moved the maximum travelling distance from the position, at which it blocks the scanner home sensor (PS201). C6103: The scanner home sensor (PS201) detects the scanner at its home position during a period of time that begins with the time when a prescan command and a scan preparation command are executed and ends when a home return command is executed.
Causes: • Scanner home sensor (PS201) • Scanner motor (M201) • Scanner drive board (SCDB) • MFP board (MFPB)
Remedy: 1. Correct or change the scanner drive (pulley, gear, belt) if it is faulty. 2. Correct the scanner motor set screw if loose. 3. Adjust [Image Position: Leading Edge] and [Sub Scan Zoom Adj.]. 4. Check the connector between M201-SCDB CN4 for proper connection and correct as necessary. 5. Check the connector between PS201-SCDB CN6 for proper connection and correct as necessary. 6. Check the connector between SCDB CN2-MFPB CN12E for proper connection and correct as necessary. 7. PS201 I/O check, sensor check • Control signal: SCDB CN6-3 (ON) • Location of electrical component: 25-P 8. M201 operation check • Control signal: SCDB CN4-1 to 4 • Location of electrical component: 26-P 9. Replace SCDB. 10. Replace MFPB.