Code: 004A
Description: Cooling fan motor malfunction • The cooling fan motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the cooling fan motor is being rotated.
Causes: • Cooling fan motor (FM11) • Printer control board (PRCB)
Remedy: 1 Check the connector between FM11-relay CN29- PRCB CN10 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM11 operation check PRCB CN10-5 (REM) PRCB CN10-7 (LOCK) 5-E 4 Replace FM11. 5 Replace PRCB.