Code: 0094
Description: 2nd transfer pressure / retraction failure • The IDC sensor does not come into the condition where the level detection is available (retracted position = IDC sensor shutter is open) within a given period of time after the 2nd transfer pressure solenoid has turned ON. • The IDC sensor does not come into the condition where the level detection is not available (pressed position = IDC sensor shutter is closed) within a given period of time after the 2nd transfer pressure solenoid has turned ON.
Causes: • IDC sensor (IDCS) • Transport motor (M2) • 2nd transfer pressure solenoid (SD2) • Printer control board (PRCB)
Remedy: 1 Check the connector between M2-PRCB CN11 for proper connection and correct as necessary. 2 Check the M2 connector for proper drive coupling and correct as necessary. 3 Check the connector between IDCS-PRCB CN19 for proper connection and correct as necessary. 4 Check the connector between SD2-relay CN23-PRCB CN24 for proper connection and correct as necessary. 5 IDCS sensor check PRCB CN19-1 (IDC_D_LEFT) PRCB CN19-4 (IDC_CTL_LEFT) 13-K 6 SD2 operation check PRCB CN24-6 (REM) 5-D 7 M2 operation check PRCB CN11-10 to 13 13-B to C 8 Replace SD2. 9 Replace M2. 10 Replace IDCS. 11 Replace PRCB.