Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 0094 — Konica-Minolta bizhub C3100P

Code: 0094

Description: 2nd transfer pressure / retraction failure • The IDC sensor does not come into the condition where the level detection is available (retracted position = IDC sensor shutter is open) within a given period of time after the 2nd transfer pressure solenoid has turned ON. • The IDC sensor does not come into the condition where the level detection is not available (pressed position = IDC sensor shutter is closed) within a given period of time after the 2nd transfer pressure solenoid has turned ON.
Causes: • IDC sensor (IDCS) • Transport motor (M2) • 2nd transfer pressure solenoid (SD2) • Printer control board (PRCB)
Remedy: 1 Check the connector between M2-PRCB CN11 for proper connection and correct as necessary. 2 Check the M2 connector for proper drive coupling and correct as necessary. 3 Check the connector between IDCS-PRCB CN19 for proper connection and correct as necessary. 4 Check the connector between SD2-relay CN23-PRCB CN24 for proper connection and correct as necessary. 5 IDCS sensor check PRCB CN19-1 (IDC_D_LEFT) PRCB CN19-4 (IDC_CTL_LEFT) 13-K 6 SD2 operation check PRCB CN24-6 (REM) 5-D 7 M2 operation check PRCB CN11-10 to 13 13-B to C 8 Replace SD2. 9 Replace M2. 10 Replace IDCS. 11 Replace PRCB.

← Xem tất cả mã lỗi Konica-Minolta bizhub C3100P

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie