Mã lỗi 0096 — Konica-Minolta bizhub C3100P

Code: 0096

Description: 1st transfer pressure / retraction failure • The 1st transfer pressure sensor is not activated (retracted position) within a given period of time after the 1st transfer pressure solenoid has turned ON. • The 1st transfer pressure sensor is not deactivated (pressed position) within a given period of time after the 1st transfer pressure solenoid has turned ON.
Causes: • 1st transfer pressure sensor (PS17) • Transport motor (M2) • 1st transfer pressure solenoid (SD1) • Printer control board (PRCB)
Remedy: 1 Check the connector between M2-PRCB CN11 for proper connection and correct as necessary. 2 Check the M2 connector for proper drive coupling and correct as necessary. 3 Check the connector between PS17-PRCB CN9 for proper connection and correct as necessary. 4 Check the connector between SD1-relay CN25-PRCB CN7 for proper connection and correct as necessary. 5 PS17 sensor check PRCB CN9-6 (ON) 12-J 6 SD1 operation check PRCB CN7-4 (REM) 13-D 7 M2 operation check PRCB CN11-10 to 13 13-B to C 8 Replace PS17. 9 Replace SD1. 10 Replace M2. 11 Replace PRCB.