Code: 6751
Description: Lamp lights on and AFE gain adjustment failure. During the AFE gain adjustment, the error occurs continuously for three times after retrying in a state that the the peek value of the output data is 64 or less.
Causes: • Scanner unit • MFP board (MFPB)
Remedy: 1 Check the connector between scanner unit-MFPB CN102 for proper connection and correct as necessary. 2 Check for possible extraneous light and correct as necessary. 3 Clean the lens, mirrors, AFE surface, and shading sheet if dirty. 4 Correct reflective mirror of the scanner if faulty, or change scanner mirror. 5 Replace the scanner unit. 6 Replace MFPB.