Description: Transfer belt contact fault after K pressure established The 1st transfer pressure sensor (PS9) is turned ON (blocked) after the lamps of given time after the 1st transfer pressure solenoid (SD1) turned OFF when the release operation is finished.
Causes: • Main motor (M1) • 1st transfer pressure solenoid (SD1) • 1st transfer pressure sensor (PS9) • MFP board (MFPB)
Remedy: 1. Check the connector between M1-MFPB CN6E for proper connection and correct as necessary. 2. Check the connector of M1 for proper drive coupling and correct as necessary. 3. Check the connector between PS9-MFPB CN9E for proper connection and correct as necessary. 4. Check the connector between SD1-relay CN85-MFPB CN9E for proper connection and correct as necessary. 5. PS9 I/O check, sensor check • Control signal: MFPB CN9E-3 (ON) • Location of electrical component: 3-C 6. SD1 operation check • Control signal: MFPB CN9E-12 (REM) • Location of electrical component: 4-C 7. M1 operation check • Control signal: MFPB CN6E-4 to 7 • Location of electrical component: 2-C 8. Replace M1. 9. MFPB F4E conduction check 10. Replace MFPB.