Description: Fusing disconnection error detection (difference of temperature) The difference between the temperature corrected by the fusing temperature sensor/1 (TEM1: center) and the temperature detected by the fusing temperature sensor/1 (TEM1: edge) exceeds a predetermined value after warm up.
Causes: • Fusing unit • Fusing temperature sensor/1 (TEM1: center) • Fusing temperature sensor/1 (TEM1: edge) • DC power supply (DCPS) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. DCPS F102 conduction check 7. Replace DCPS.