Description: • C5102: Main motor failure to turn • C5103: Main motor turning at abnormal timing Trouble detection condition • C5102: The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. • C5103: The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: • Main motor (M1) • MFP board (MFPB)
Remedy: 1. Check the connector between M1-MFPB CN6E for proper connection and correct as necessary. 2. M1 operation check • Control signal: MFPB CN6E-4 to 7 • Location of electrical component: 2-C 3. Replace M1. 4. MFPB F9E conduction check 5. Replace MFPB.