Description: Exposure lamp lighting failure detected. The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment.
Causes: • Scanner unit • MFP board (MFPB)
Remedy: 1. Check the connector between scanner unit-MFPB CN23, CN103 for proper connection and correct as necessary. 2. Check for possible extraneous light and correct as necessary. 3. Clean the lens, mirrors, CCD surface, and shading sheet if dirty. 4. Replace the scanner unit. 5. MFPB ICP7, PTC802E conduction check 6. Replace MFPB.