Code: C0094
Description: 2nd Image Transfer Roller pressure/retraction failure
• The 2nd Image Transfer Pressure Position Sensor is not activated (retracted position) within 2 sec. after the 2nd Image Transfer Pressure/Retraction Motor has started turning during a sequence of the 2nd Image Transfer Roller's retracting motion. • The 2nd Image Transfer Pressure Position Sensor is not deactivated (pressed position) within 2 sec. after the 2nd Image Transfer Pressure/Retraction Motor has started turning during a sequence of the 2nd Image Transfer Roller's pressing motion.
• The 2nd Image Transfer Pressure Position Sensor is not activated (retracted position) within 2 sec. after the 2nd Image Transfer Pressure/Retraction Motor has started turning during a sequence of the 2nd Image Transfer Roller's retracting motion. • The 2nd Image Transfer Pressure Position Sensor is not deactivated (pressed position) within 2 sec. after the 2nd Image Transfer Pressure/Retraction Motor has started turning during a sequence of the 2nd Image Transfer Roller's pressing motion.
Remedy: 1 Check the M13 connector for proper connection and correct as necessary. 2 PC29 I/O check PWB-MC PJ12MC-9A (ON) 6-B. 3 M13 operation check PWB-MC PJ18MC-1 (REM) 6-A. 4 Change PWB-MC.