Description: Color PC Drum Motor's turning at abnormal timing
• The Motor Lock signal remains LOW for a predetermined continuous period of time while the Motor remains stationary.
Remedy: 1 M5 operation check PWB-MC PJ33MC-10 (REM) PWB-MC PJ33MC-13 (LOCK) C to D- 18 to 19. 2 Change PWB-MC.