Mã lỗi C3101 — Konica-Minolta bizhub C351

Code: C3101

Description: Fusing Pressure Roller pressure/retraction failure
• No change is observed in the encoder sensor pulse even after the lapse of 0.5 sec. after the Fusing Pressure/Retraction Motor has started turning for a sequence of the Fusing Pressure Roller’s retracting motion. • No change is observed in the encoder sensor pulse even after the lapse of 0.5 sec. after the Fusing Pressure/Retraction Motor has started turning for a sequence of the Fusing Pressure Roller’s pressing motion. • The Fusing Pressure Position Sensor is not activated (pressed position) even when 30 encoder sensor pulses are counted after the Fusing Pressure/Retraction Motor has started turning for a sequence of the Fusing Pressure Roller’s pressing motion.
Remedy: 1 Check the M9 connector for proper connection and correct as necessary. 2 PC33 I/O check PWB-MC PJ26MC-12 (ON). 3 PC33 operation check. 4 M19 operation check PWB-MC PJ14MC-5 to 6 C to D-6. 5 Change Fusing Unit. 6 Change PWB-MC.