Code: C2151
Description: 2nd image transfer roller separation
• The 2nd image transfer pressure position sensor doesn’t turn ON (retracting) even after the lapse of a given period of time after the 2nd image transfer pressure/retraction motor has started rotating during the 2nd image transfer roller is retracting. • The 2nd image transfer pressure position sensor doesn’t turn OFF (pressuring) even after the lapse of a given period of time after the 2nd image transfer pressure/retraction motor has started rotating during the 2nd image transfer roller is pressuring.
• The 2nd image transfer pressure position sensor doesn’t turn ON (retracting) even after the lapse of a given period of time after the 2nd image transfer pressure/retraction motor has started rotating during the 2nd image transfer roller is retracting. • The 2nd image transfer pressure position sensor doesn’t turn OFF (pressuring) even after the lapse of a given period of time after the 2nd image transfer pressure/retraction motor has started rotating during the 2nd image transfer roller is pressuring.
Remedy: 1 Check the connector of motor for proper connection and correct as necessary. 2 Change the right door assy and MFPB.