Code: C3752
Description: Abnormal high temp. (press)
• The temperature of the fusing pressure roller thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly before the Heater temperature control starts. • The temperature of the fusing pressure roller thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly after the heater temperature control starts.
• The temperature of the fusing pressure roller thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly before the Heater temperature control starts. • The temperature of the fusing pressure roller thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly after the heater temperature control starts.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit, MFPB and DCPU for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change MFPB. 6 Change DCPU.