Mã lỗi 0094 — Konica-Minolta bizhub C35P

Code: 0094

Display: XFER DETACH 2
Description: 2nd image transfer pressure / retraction failure
• The IDC sensor does not come into the condition where the level detection is available (retracted position = IDC sensor shutter is open) within a given period of time after the 2nd transfer release solenoid has turned ON.
• The IDC sensor does not come into the condition where the level detection is not available (pressed position = IDC sensor shutter is closed) within a given period of time after the 2nd transfer release solenoid has turned ON.
Remedy: 1 Check the connector between M2-PRCB PJ11 for proper connection and correct as necessary. 2 Check the M2 connector for proper drive coupling and correct as necessary. 3 Check the connector between IDC-PRCB PJ19 for proper connection and correct as necessary. 4 Check the connector between SD2-relay CN23-PRCB PJ24 for proper connection and correct as necessary. 5 IDC sensor check. 6 SD2 operation check. 7 M2 operation check. 8 Change SD2. 9 Change M2. 10 Change IDC. 11 Change PRCB.