Code: C0213
Description: LCT shift gate malfunction
• The division board position sensor (PS14) cannot be set to L even after the set period of time has elapsed after the operation of the division board position motor (M3) began with the division board position sensor (PS14) set to L.
• The division board position sensor (PS14) cannot be set to L even after the set period of time has elapsed after the operation of the division board position motor (M3) began with the division board position sensor (PS14) set to L.
Remedy: 1 Check the connector between PS14-PCCB CN2<B> for proper connection and correct as necessary. 2 Check the connector between M3-PCCB CN2<B> for proper connection and correct as necessary. 3 Check the connector of each motor for proper drive coupling, and correct as necessary. 4 PS14 I/O check, sensor check. 5 M3 operation check. 6 Change PCCB.