Mã lỗi C0214 — Konica-Minolta bizhub C360

Code: C0214

Description: LCT shifting failure
• The shifter stop position sensor (PS11) is not blocked even after the set period of time has elapsed after the shift operation began (shift to the right). • The shifter stop position sensor (PS11) is not blocked even after the set pulse is detected by the shift motor pulse sensor (PS8) after the shift operation began (shift to the right). • The shifter home position sensor (PS12) is not unblocked even after the set pulse is detected by the shift motor pulse sensor (PS8) after the shift operation began (shift to the right). • The shifter home position sensor (PS12) is not blocked even after the set period of time has elapsed after the return operation began (shift to the left). • The shifter home position sensor (PS12) is not blocked even after the set pulse is detected by the shift motor pulse sensor (PS8) after the return operation began (shift to the left). • The shifter stop position sensor (PS11) is not unblocked even after the set pulse is detected by the shift motor pulse sensor (PS8) after the return operation began (shift to the left).
Remedy: 1 Check the connector between PS8-PCCB CN2<A> for proper connection and correct as necessary. 2 Check the connector between PS11-PCCB CN2<A> for proper connection and correct as necessary. 3 Check the connector between PS12-PCCB CN2<A>for proper connection and correct as necessary. 4 PS8 I/O check, sensor check. 5 PS11 I/O check, sensor check. 6 PS12 I/O check, sensor check. 7 Change PCCB.

← Xem tất cả mã lỗi Konica-Minolta bizhub C360

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie