Code: C1150
Description: Center-staple rear adjust drive motor malfunction
<When FS-527+SD-509 is installed> • The center staple alignment home sensor/R (PS41) is turned neither ON nor OFF even after the set period of time has elapsed after the center staple alignment motor/R (M23) is turned ON.
<When FS-527+SD-509 is installed> • The center staple alignment home sensor/R (PS41) is turned neither ON nor OFF even after the set period of time has elapsed after the center staple alignment motor/R (M23) is turned ON.
Remedy: 1 Check the connector between M23-SDDB PJ7 for proper connection and correct as necessary. 2 Check the connector between PS41-SDDB PJ9 for proper connection and correct as necessary. 3 Check the connector of M23 for proper drive coupling, and correct as necessary. 4 PS41 I/O check, sensor check. 5 M23 operation check. 6 Change M23. 7 Change SDDB. 8 Change FSCB.