Code: C1182

Description: Shift motor drive malfunction
<When JS-505 is installed> • The shift home sensor (PS6) is not blocked after the set period of time has elapsed after the shift motor (M2) is turned ON (start of moving to the home position.) • The shift home sensor (PS6) is not unblocked twice in a row after the set period of time has elapsed after the shift motor (M2) is turned ON (start of moving to the shift position.) <When FS-527 is installed> • When moving to the front (home) position: The tray 2 shift home sensor (PS25) is not turned ON even after the set period of time has elapsed after the tray 2 shift motor (M16) is turned ON. • When moving to the rear (shift) position: The tray 2 shift home sensor (PS25) is not turned OFF even after the set period of time has elapsed after the tray 2 shift motor (M16) is turned ON.
Remedy: When JS-505 is installed: 1 Check the connector between M2-JSCB PJ4 for proper connection and correct as necessary. 2 Check the connector between PS6-JSCB PJ7 for proper connection and correct as necessary. 3 Check the connector of M2 for proper drive coupling, and correct as necessary. 4 PS6 I/O check, sensor check. 5 M2 operation check. 6 Change M2. 7 JSCB F6 conduction check. 8 Change JSCB.
When FS-527 is installed: 1 Check the connector between M16-FSCB PJ5 for proper connection and correct as necessary. 2 Check the connector between PS25-FSCB PJ21 for proper connection and correct as necessary. 3 Check the connector of M16 for proper drive coupling, and correct as necessary. 4 PS25 I/O check, sensor check. 5 M16 operation check. 6 Change M16. 7 Change FSCB.

← Xem tất cả mã lỗi Konica-Minolta bizhub C360

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie