Code: C11E0
Description: Duplex path switching motor drive malfunction
<When FS-527 is installed> • The duplex path switching sensor (PS3) is turned neither ON nor OFF even after the set period of time has elapsed after the duplex path switching motor (M2) is turned ON.
<When FS-527 is installed> • The duplex path switching sensor (PS3) is turned neither ON nor OFF even after the set period of time has elapsed after the duplex path switching motor (M2) is turned ON.
Remedy: When FS-527 is installed: 1 Check the connector between M2-FSCB PJ29 for proper connection and correct as necessary. 2 Check the connector between PS3-FSCB PJ11 for proper connection and correct as necessary. 3 Check the connector of M2 for proper drive coupling, and correct as necessary. 4 PS3 I/O check, sensor check FSCB PJ11-6. 5 M2 operation check FSCB PJ29-1 to 3. 6 Change M2. 7 Change FSCB.