Code: C3423
Description: Fusing heaters trouble (Pressurizing side)
• Detected temperature of the pressure roller thermistor does not go up a given range of temperature even after a lapse of given period of time at warm up. • Detected temperature of the pressure roller thermistor does not reach to a given temperature even after a lapse of given period of time after warm up is completed.
• Detected temperature of the pressure roller thermistor does not go up a given range of temperature even after a lapse of given period of time at warm up. • Detected temperature of the pressure roller thermistor does not reach to a given temperature even after a lapse of given period of time after warm up is completed.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary. 4 Change fusing unit. 6 Change PRCB. 7 Change DCPU.