Code: C8103
Description: Lift up mechanism trouble (Upward movement)
• The lift up upper sensor (PS16) is not turned ON after a lapse of a given time after the lift-up motor (M7) moves up (is turned forward).
• The lift up upper sensor (PS16) is not turned ON after a lapse of a given time after the lift-up motor (M7) moves up (is turned forward).
Remedy: 1 Check the connector between M7-DFCB PJ5 for proper connection and correct as necessary. 2 Check the connector between PS16-DFCB PJ11 for proper connection and correct as necessary. 3 Check the connector of M7 for proper drive coupling, and correct as necessary. 4 PS16 I/O check, sensor check DFCB PJ11-3 (ON) DF-617 B to C-7. 5 M7 operation check DFCB PJ5-6 to 9 DF-617 I-5. 6 Change M7. 7 Change DFCB.