Mã lỗi C0210 — Konica-Minolta bizhub C364

Code: C0210

Description: LCT lift failure
• The main tray upper limit sensor (PS136) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began. • The shifter stop / lower limit position sensor (PS138) is not unblocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began. • The main tray upper limit sensor (PS136) is not blocked even after the set period of time has elapsed after the paper lift-up operating. • The main tray upper limit sensor (PS136) is not unblocked even after the set period of time has elapsed after the paper lift-down operation began. • The shifter stop / lower limit position sensor (PS138) is not blocked even after the set period of time has elapsed after the paper lift-down operation began.
Remedy: 1 Check the connector between M134-PCCB CN10 for proper connection and correct as necessary. 2 Check the connector of M134 for proper drive coupling and correct as necessary. 3 Check the connector between PS136-relay CN1- PCCB CN4 for proper connection and correct as necessary. 4 Check the connector between PS138-relay CN16- PCCB CN14 for proper connection and correct as necessary. 5 PS136 I/O check, sensor check PCCB CN4-3 (ON) PC-410 8-J. 6 PS138 I/O check, sensor check PCCB CN14-6 (ON) PC-410 4-J. 7 M134 operation check PCCB CN10-1 to 2 PC-410 6-J. 8 Replace M134. 9 PCCB IC2 conduction check. 10 Replace PCCB.

← Xem tất cả mã lỗi Konica-Minolta bizhub C364

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie