Mã lỗi C0211 — Konica-Minolta bizhub C368

Code: C0211

Description: Manual feed up/down abnormality. • Paper is not turned OFF (unblock) the bypass lift-up position sensor (PS26) even after the transport motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position. • The bypass lift-up position sensor (PS26) is not turned ON (blocked) even after the transport motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position.
Causes: • Transport motor (M1) • Bypass pick-up solenoid (SD1) • Bypass lift-up position sensor (PS26) • MFP board (MFPB)
Remedy: 1. Check the connector between M1-MFPB CN8E for proper connection and correct as necessary. 2. Check the connector of M1 for proper drive coupling and correct as necessary. 3. Check the connector between PS26-relay CN19-MFPB CN18E for proper connection and correct as necessary. 4. Check the connector between SD1-relay CN21-relay CN19-MFPB CN18E for proper connection and correct as necessary. 5. PS26 I/O check, sensor check • Control signal: MFPB CN18E-13 (ON) • Location of electrical component: 22-J 6. SD1 operation check • Control signal: MFPB CN18E-10 (ON) • Location of electrical component: 22-J 7. M1 operation check • Control signal: MFPB CN8E-3 (REM), MFPB CN8E-6 (LOCK) • Location of electrical component: 2-C 8. Replace M1. 9. MFPB ICP3E conduction check 10. Replace MFPB.

← Xem tất cả mã lỗi Konica-Minolta bizhub C368

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie