Description: LCT up/down abnormality (When LU-302 is installed) The upper limit sensor (PS2) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Causes: • Upper limit sensor (PS2) • Lift-up motor (M1) • LU drive board (LUDB)
Remedy: 1. Check the connector between M1-LUDB CN3 for proper connection and correct as necessary. 2. Check the connector of M1 for proper drive coupling and correct as necessary. 3. Check the connector between PS2-relay CN3-LUDB CN5 for proper connection and correct as necessary. 4. PS2 I/O check, sensor check • Control signal: LUDB CN5-3 (ON) • Location of electrical component: LU-302 4-G 5. M1 operation check • Control signal: LUDB CN3-4 (ON) • Location of electrical component: LU-302 3-G 6. Replace M1. 7. Replace LUDB.