Description: • C2551: Abnormally low toner density detected cyan TCR sensor • C2553: Abnormally low toner density detected magenta TCR sensor • C2555: Abnormally low toner density detected yellow TCR sensor. When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper.
Remedy: 1. Perform image troubleshooting procedure if image density is low. 2. Reinstall developing unit. 3. Reinstall toner cartridge. 4. Check the connector between the developing unit-FRB CN14 (C2551), CN15 (C2553), CN16 (C2555) for proper connection and correct as necessary. 5. Check the connector between FRB CN1, CN3-MFPB CN4E, CN11E for proper connection and correct as necessary. 6. M10 operation check • Control signal: MFPB CN16E-1 to 4 • Location of electrical component: 15-C 7. M7, M8, M9 operation check • Control signal: MFPB CN16E-5 to 8 (M7), MFPB CN16E-9 to 12 (M8), MFPB CN16E-13 to 16 (M9) • Location of electrical component: 15-C (M7, M8), 16-C (M9) 8. If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them. 9. Replace the developing unit. 10. Replace FRB. 11. Replace MFPB.