Mã lỗi CD015 — Konica-Minolta bizhub C368

Code: CD015

Description: HDD mirroring error master slave. A R/W error occurs in both drives during mirroring.
Causes: • Hard disk (A) (HDD (A)) • Hard disk (B) (HDD (B): HD-524)
Remedy: 1. Turn OFF the main power switch, wait for 10 sec., then turn the switch ON. 2. Replace both hard disk (A) and hard disk (B) with new ones. 3. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] and perform physical format. 4. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] and perform logical format. 5. If HDD Data Backup has previously been performed, select [Service Mode] -> [Enhanced Security] -> [HDD Data Backup] -> [Restore] and perform the function. 6. If HDD Data Backup has not been performed previously, install voice data, etc.