Code: 2562
Description: Magenta TCR sensor failure
TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Causes: • Imaging unit/Y,M,C,K • Printer control board (PRCB)
Remedy: 1 Reinstall imaging unit - - 2 Check the connector between imaging unit-PRCB CN18, CN19 for proper connection and correct as necessary. - - 3 Replace the imaging unit - - 4 Replace PRCB