Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 3921 — Konica-Minolta bizhub C3850

Code: 3921

Description: Fusing sensor wire breaks abnormality (Center of the heating roller)
After a predetermined period of time after the warm-up stage is started, the fusing temperature sensor/1 (TEM1: main of the heating side) voltage does not increase by predetermined steps (temperature rise) within a predetermined period of time.
Causes: • Fusing unit • Fusing temperature sensor/1 (TEM1: main of the heating side) • DC power supply (DCPS) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). - - 2 Check the open/close operation of the upper right door. - - 3 Check the fusing unit-PRCB CN15, DCPS CN2 for proper connection and correct or change as necessary. - - 4 Replace the fusing unit - - 5 Replace DCPS - - 6 Replace PRCB

← Xem tất cả mã lỗi Konica-Minolta bizhub C3850

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie