Code: 5353
Description: Cooling fan motor/2 failure
The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Cooling fan motor/2 (FM6)ning. • Printer control board (PRCB)
Remedy: 1 Check the connector between FM6-relay CN302- PRCB CN3 for proper connection and correct as necessary. - - 2 Check the fan for possible overload and correct as necessary. - - 3 FM6 operation check PRCB CN3-4 (OUT) PRCB CN3-6 (LOCK) 7-K 4 Replace FM6 - - 5 PRCB F2 conduction check - - 6 Replace PRCB