Description: Manual feed up/down abnormality • The manual tray liftup position sensor (PS14) is not turned ON (unblocked) even after the manual tray liftup motor (M7) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position. • The manual tray liftup position sensor (PS14) is not turned OFF (blocked) even after the manual tray liftup motor (M7) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position.
Causes: • Manual tray liftup motor (M7) • Manual tray liftup position sensor (PS14) • MFP board (MFPB)
Remedy: 1. Check the connector between M7-relay CN205-relay CN203-MFPB CN25E for proper connection and correct as necessary. 2. Check the connector of M7 for proper drive coupling and correct as necessary. 3. Check the connector between PS14-relay CN203-MFPB CN25E for proper connection and correct as necessary. 4. PS14 I/O check, sensor check • Control signal: MFPB CN25E-5 (ON) • Location of electrical component: 8-C 5. M7 operation check • Control signal: MFPB CN25E-1 to 2 • Location of electrical component: 7-C 6. Replace M7. 7. MFPB F11E conduction check 8. Replace MFPB.