Code: C1103
Description: CD alignment motor/Fr malfunction <bizhub C3851FS> • The CD alignment plate home sensor/Fr (FSPS2) is not turned OFF (unblocked) even after the lapse of a given period of time after the CD alignment motor/Fr (FSM2) is turned ON at start from the home position. • The CD alignment motor/Fr (FSM2) is not drive completion after the set period of time has elapsed even after the start of driving. • The CD alignment plate home sensor/Fr (FSPS2) is not turned ON (blocked) even after the lapse of a given period of time after the CD alignment motor/Fr (FSM2) is turned ON at the initial operation.
Causes: • CD alignment motor/Fr (FSM2) • CD alignment plate home sensor/Fr (FSPS2) • FS control board (FSCB)
Remedy: 1. Check the connector between FSM2-relay CN22-FSCB CN10 for proper connection and correct as necessary. 2. Check the connector of FSM2 for proper drive coupling, and correct as necessary. 3. Check the connector between FSPS2-FSCB CN10 for proper connection and correct as necessary. 4. FSPS2 I/O check, sensor check • Control signal: FSCB CN10-7 • Location of electrical component: 24-Q 5. FSM2 operation check • Control signal: FSCB CN10-1 to 4 • Location of electrical component: 24-Q 6. Replace FSM2. 7. Replace FSCB.