Description: Output tray paper holding motor malfunction <bizhub C3851FS> The output tray full sensor (FSPS6) is not turned ON (blocked) and no paper are ejected on the output tray even after the lapse of a given period of time after the output tray paper holding motor (FSM6) is turned ON when returning to the home position.
Causes: • Output tray paper holding motor (FSM6) • Output tray full sensor (FSPS6) • FS control board (FSCB)
Remedy: 1. Check the connector between FSM6-relay CN39-FRCB CN9 for proper connection and correct as necessary. 2. Check the connector of FSM6 for proper drive coupling, and correct as necessary. 3. Check the connector between FSPS6-relay CN39-FRCB CN9 for proper connection and correct as necessary. 4. FSPS6 I/O check, sensor check • Control signal: FSCB CN9-8 • Location of electrical component: 24-W 5. FSM6 operation check • Control signal: FSCB CN9-12 to13 • Location of electrical component: 25-W 6. Replace FSM6. 7. FSCB PTC1 conduction check 8. Replace FSCB.