Description: Transfer belt fault at initial position return The 1st transfer pressure sensor (PS9) is unable to detect "switch from retraction to pressure" or "switch from pressure to retraction" within a given period time after the 1st transfer pressure solenoid (SD1) turned ON during an initial position return.
Causes: • Main motor (M1) • 1st transfer pressure solenoid (SD1) • 1st transfer pressure sensor (PS9) • MFP board (MFPB)
Remedy: 1. Check the connector between M1-MFPB CN6E for proper connection and correct as necessary. 2. Check the connector of M1 for proper drive coupling and correct as necessary. 3. Check the connector between PS9-MFPB CN9E for proper connection and correct as necessary. 4. Check the connector between SD1-relay CN85-MFPB CN9E for proper connection and correct as necessary. 5. PS9 I/O check, sensor check • Control signal: MFPB CN9E-3 (ON) • Location of electrical component: 3-C 6. SD1 operation check • Control signal: MFPB CN9E-12 (REM) • Location of electrical component: 4-C 7. M1 operation check • Control signal: MFPB CN6E-4 to 7 • Location of electrical component: 2-C 8. Replace M1. 9. MFPB F4E conduction check 10. Replace MFPB.