Description: Cooling fan motor/1 failure The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Cooling fan motor/1 (FM2) • MFP board (MFPB)
Remedy: 1. Check the connector between FM2-relay CN303-MFPB CN12E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM2 operation check • Control signal: MFPB CN12E-9 (LOCK) • Location of electrical component: 26-C 4. Replace FM2. 5. MFPB F2E conduction check 6. Replace MFPB.